CC Blog • Quick Bits • Resources

BJT Safe Operating Area

Written by Andrew Levido

If you have ever taken a close look at a data sheet for a power transistor you have probably noticed the “Safe Operating Area” curves. These are very important for designing linear power circuits such as amplifiers and power supplies, but not everyone knows how they can be used.

A safe operating area (SOAR) curve simply describes the range of voltages and currents over which a device can be operated without damage. Figure 1 shows the safe operating area curve for a the MJE2955 (PNP) andMJE3055 (NPN) complimentary 10A 60V power transistors taken from the data sheet.

Figure 1
The safe operating area curve for the MJE2955/MJE3055 transistors is bounded by four constraints. Apart from the device VCE and IC limits there is an overall power limit (shown here as thermally limited) and a second breakdown limit discussed in the text.

The vertical axis collector current, and the horizontal axis is collector-emitter voltage – both shown on logarithmic scales. For BJTs such as these, the safe operating area is bounded by four different limits, each corresponding to one of the line segments. Note that there are different curves for continuous operation and for non-repetitive pulses of various durations. We will focus on the continuous (DC) curve.

At low VCE, IC is limited to 10A by the design of the transistor – in this case by the bond wires that connect the silicon die to the external pins. Similarly, the VCE at low levels of IC, shown at the bottom right, is limited to the 60V rating of the transistor. These limits correspond to the headline data sheet parameters IC and VCEO.

We can’t however operate the transistor with a 10A collector current and a collector-emitter voltage of 60V at the same time since we would be dissipating a whopping 600W. There is therefore a power limit which appears as the first sloped section of the SOAR curve labelled “thermally limited”. This corresponds to the maximum power, PTOT, defined in the data sheet (75W in this case).

The power limit does not however extend to higher values of VCE. You can see there is one further limit shown by the steeper line segment labelled the “second breakdown” limit.

Second breakdown occurs in a large area (high current) bipolar transistor because the collector current does not flow evenly through the entire cross-section of the junction. In some areas there will be a slightly higher concentration of current and therefore a localised temperature rise. This heating causes that specific area of silicon to become even more conductive, leading to more current being concentrated at that spot and yet more heating. This positive feedback eventually results in a localised breakdown of the silicon and the destruction of the transistor.

Now that we what the SOAR curve is, let’s look at how we can use it in a practical (albeit simplified) example. Say we want to build a simple 30W class AB amplifier using an MJE2955/MJE3055 pair as shown in Figure 2. The load is a loudspeaker represented by the first-order approximation of a resistor and inductor in series.

Figure 2
In our simple example we use a pair of complementary transistors in a class AB arrangement driving a complex load consisting of a resistive and an inductive element. We want to ensure the transistor VCE and IC are inside the safe operating limits while driving 30W into the load with ±25V power rails.

To check that the output transistors are operating in the safe area we need to plot the collector-emitter voltage and collector current on the SOAR curve and check it is within the safe area. I have used a supply voltage of ±25V and a complex load impedance of 5.7-j5.7Ω (corresponding to 8Ω ∠45˚).

Figure 3 shows the one of the output transistor’s VI characteristics plotted over one cycle of a sinusoid on linear axes. The result is a loop because the voltage and current are out of phase. You can easily make this plot with a spreadsheet.

Figure 3
Here the transistor VCE and IC are plotted over one full cycle of a sinusoid for the example of Figure 2. The characteristic is an open loop because the current and voltage are out of phase due to the nature of the load. The axes are linear in this example.

Finally Figure 4 shows the same data plotted on logarithmic axes, along with the DC SOAR limits in red. Actually, this graph only shows one half cycle of the sinusoid since each output transistor will only conduct for one half-cycle while the current through it is positive. You can see that the with this load the output transistors are operating well within the safe area, so these transistors are suitable for our application.

Figure 4
This is one half-cycle of the same data as Figure 3 plotted this time on logarithmic axes, and with the safe operating limits superimposed. You can see that the transistor operating locus remains well within the safe area.

If we were to use this amplifier with a 4Ω ∠45˚ load impedance (2.8-j2.8Ω) we get the result shown in Figure 5. Here the V-I curve touches the safe operating area so we would have to conclude that it is not safe to use these devices in these circumstances. This is despite the headline specifications (60V and 10A) suggesting the transistors would be adequate.

Figure 5
If we try driving 30W into a nominal 4Ω complex load (2.8-j2.8Ω) we see that the transistor VI locus intersects the safe operating limits. We can’t use these devices safely in this case.
Keep up-to-date with our FREE Weekly Newsletter!

Don't miss out on upcoming issues of Circuit Cellar.


Note: We’ve made the Dec 2022 issue of Circuit Cellar available as a free sample issue. In it, you’ll find a rich variety of the kinds of articles and information that exemplify a typical issue of the current magazine.

Would you like to write for Circuit Cellar? We are always accepting articles/posts from the technical community. Get in touch with us and let's discuss your ideas.

Sponsor this Article
+ posts

Andrew Levido (andrew.levido@gmail.com) earned a bachelor’s degree in Electrical Engineering in Sydney, Australia, in 1986. He worked for several years in R&D for power electronics and telecommunication companies before moving into management roles. Andrew has maintained a hands-on interest in electronics, particularly embedded systems, power electronics, and control theory in his free time. Over the years he has written a number of articles for various electronics publications and occasionally provides consulting services as time allows.

Supporting Companies

Upcoming Events


Copyright © KCK Media Corp.
All Rights Reserved

Copyright © 2026 KCK Media Corp.

BJT Safe Operating Area

by Andrew Levido time to read: 4 min