What Are Accuracy and Resolution and How Do They Relate?
When you’re testing components you need some resolution of accuracy and some level of precision. The two are absolutely not the same, but the accuracy will never be any better than the resolution. Understanding the meaning and application of each term will let you ensure that the results are useful for your purpose.
Many years ago, when I was 15, I worked in a television repair shop. This was before college, before I got an engineering degree, before I could even drive. One of the instruments in the shop was an old vacuum tube voltmeter (VTVM) used to measure voltages. This was built before digital voltmeters existed. It used a wide analog dial, maybe 6” across, with a strip of mirror behind it.
The top of Figure 1 shows a simplified drawing of the meter voltage scale that reads from 0V to 50V. Like any analog voltmeter, the probes are connected to the voltage, and the needle swings to indicate the correct voltage on the scale. So why the mirror? The bottom of Figure 1 shows why; the needle can’t touch the meter face. The meter movement doesn’t have enough force to move the needle if there is any significant friction, and the needle would eventually wear away the markings on the dial. So the needle has to be suspended by the needle shaft just slightly above the meter face.
Now imagine that you are taking a reading and the needle indicates 30V. If you move your head to the right or left, the reading will change due to the parallax error. Your eyes aren’t perpendicular to the needle and the voltage scale. You can demonstrate this by holding your index finger in front of you and turning your head back and forth; where your finger appears to point will move with your head. The purpose of the mirror is to increase the accuracy of the reading; you would move your head until the needle exactly covers its reflection in the mirror. Then you know you are reading the correct voltage value.
ACCURACY
Accuracy is the ability to make a measurement that is close to the actual value. In the VTVM example, you want the meter to read 30V only if the voltage is really 30V. The meter could be accurate to 4 decimal places (they never were), but without the mirror, your actual reading might be off by as much as a volt or two. For the same reason, while the needles on VTVMs were very thin so that you could get a good estimate of the actual value, the width of the needle itself introduced some uncertainty into the reading.
Not all VTVMs had mirrors back then, and they could be fragile devices. You had to wait for them to warm up to get accurate readings, and you had to calibrate the meter when making resistance measurements; all kinds of issues with those meters are fixed with a modern digital multimeter (DMM). But in some cases, adding digital displays can mask those same problems.
For example, I have a DMM that specifies the voltage accuracy as 0.5% ±2. Accuracy of measuring resistance is 1% ±3. This meter is a 3½ digit meter, meaning that there are 3 significant digits and a leading value that can be 0 or 1. So all the scales are decades of 2; 0-199mV, 0-1.999V, 0-20V, 0-199V, and so forth. If I were measuring a 10V power supply output on the 20V scale, the actual reading could be 10V ±0.5%, or 9.95V to 10.05V. However, there is an additional specification for the measurement, the ±2 value. This means that the actual measurement may vary by up to two counts in the least significant digit. So the actual measurement range of that 10V output could be displayed as 9.93 to 10.07.
On the resistance scale, the accuracy is 1%. So, if you are measuring a batch of 1% resistors to match some resistors for use in a circuit that needs closely matched parts, the accuracy of your measurement is equal to the resistor accuracy. If you have a resistor that is marked 100Ω, it could be 99 or 101 just because of the resistor accuracy. But the meter adds the same uncertainty, so it could read 98 or 102 because the meter adds as much uncertainty as the resistor tolerance. In that case, you would need a better meter or to just spend the money for resistors with 0.1% tolerance.
Resolution
Some years ago, I worked for a startup that was doing automotive electronics. I was on the product design side, but since it was a startup, we all wore multiple hats. One problem they had was that some parts passing the tests on the automated manufacturing line were failing in the customer sampling (the customer would test a sample of the parts received to confirm quality). I was called in to figure out what was going on. The manufacturing line was built using automated equipment that was designed by an outside vendor.
The manufacturing engineers didn’t really understand the electrical requirements, so they took the recommendation of the vendor for the testing part of the manufacturing process. The equipment used standard modules for various functions, and one was the part that measured a voltage in the completed part. I don’t remember the voltages and tolerances that were involved, so I’ve made up some numbers to illustrate what was going on.
The parts had a specification of ±2% voltage accuracy, and the voltage was 13V. So, for the parts to be correct, the voltage had to be between 12.75V and 13.26V. The voltage measurement module designed into the equipment could measure with 8-bit accuracy. But it was limited in the voltage ranges it could measure. So, to measure the output of these parts, a 100V range had to be used. While the resolution of the measurement was 0.39% (1/256), that applied to the 100V range. That is a resolution of 100/256, or 0.39V. But the ±2% accuracy requirement applied to the nominal 13V value, not the full measurement range of the manufacturing equipment. 0.39V is 3% of 13V.
The resolution wasn’t adequate for the measurement, and the equipment would sometimes declare out-of-spec parts as in-spec. A part that read exactly 13V could actually be 12.61V to 13.4V, so it would have about a 1-in-3 chance of being out of specification.
Resolution is the smallest change that can be detected. In the VTVM, it’s the smallest meter movement that can be seen well enough by the human eye to be seen (or estimated) on the meter scale. In most MCU-based applications, it is the smallest step that can be detected by the analog-to-digital converter (ADC). And, as in the manufacturing example, the resolution as a percentage of the reading is not necessarily a percentage of the signal, but a percentage of the full ADC range (which is usually a fixed reference voltage).
So, for a signal that varies between 0V and 1V, applied to an 8-bit MCU ADC using a 3.3V reference, the resolution of the ADC is 3.3/256, or 12.8mV, or 0.39%. But 12.8mV is about 1.3% of the input signal. The smallest change you could detect in the input signal is 1.3% of the maximum value.
RESOLUTION AND ACCURACY
Resolution and accuracy are obviously tied together. Say we have a 0-1V input signal and it needs to be measured with 2% accuracy by the MCU. Can that be done with the 8-bit, 3.3V configuration? At first glance, it would appear so; the measurement accuracy of 1.3% is better than the 2% specification. But let’s do some math.
Say the input voltage is 0.5V. This will ideally read as an ADC value of 38 if the 3.3V reference is very accurate, say, 3.3000V. The actual value will be 38.8 (0.5V/12.8mV). But the ADC can’t read the fractional part. Any voltage between 0.489V and 0.501V will read as 38. Any voltage between 0.502V and 0.515V will read as 39. If two successive readings are 38 and 39, the corresponding voltages could be 0.501 and 0.502. Or they could 0.489 and 0.515, a change of just over 2% of the full-scale voltage. Yes, the MCU can detect the absolute voltage with an accuracy of 2%. But it can’t tell the size of any change to within 2%. So, the accuracy is 1.3%, but if the ADC value changes, the MCU can’t determine the size of the change any closer than 2%. Whether this is an issue depends on what the MCU has to do with changing values. The point is that the resolution of the measurement and the resolution of detecting changes in the input value are not necessarily the same. But the accuracy will never be any better than the resolution.
THINGS THAT AFFECT ACCURACY
Accuracy is, as already mentioned, how closely the measured value represents the actual thing being measured. Whether it’s a DMM display or an ADC output that is used in an automated production process, the accuracy of the measurement is important. How accurate it needs to be is dependent on how the measurement is used. Accuracy is affected by the resolution of the ADC in the previous examples. But factors other than the ADC step size affect the accuracy of the measurement.
Reference Voltages: Any system using an ADC has some reference voltage that determines the total range of voltages (or current) that can be measured. In the case of the 3.3V reference mentioned in the previous example, that might be the Vcc supply to the MCU. Many MCUs have internal ADCs that can use the Vcc supply as a reference voltage. But the source of Vcc has its own tolerance. For example, the LF33, a low-dropout linear regulator, is available in tolerance of 1%, 1.5%, and 2%. If you are using a part with 2% tolerance, and the 3.3V reference is at the low end, 3.23V, then the step size of the ADC in the previous example will be 12.6mV, not 12.8mV. A tiny difference, but if your system specification requires 1% accuracy in the measurements, you would need a better reference. The important thing is that even if you had a 16-bit ADC, the measurement accuracy will never exceed the accuracy of the reference.
Temperature: The LF33 is available in three different accuracy values, specified at 25°C. But the part is specified to operate from -40°C to 125°C. Looking at the ST LFxx datasheet, the 2% LF33 becomes a 4% part over the temperature range from -25°C to 85°C. So, if you were using this part to power an MCU and as a reference for the internal ADC over an extended temperature range, your accuracy is halved.
Improving Accuracy and Resolution: Most ADCs can convert signals from 0V to the reference voltage (3.3V in the example mentioned). There are some exceptions, but for this explanation, I’ll use the simplification that the reference voltage is the maximum ADC conversion voltage. The resolution is the reference voltage divided by the number of steps. For a 3.3V reference, an 8-bit ADC has a resolution of 3.3/256 or 12.9mV. A 10-bit ADC would have a resolution of 3.3V/1024 or 3.2mV.
Lower Reference Voltage: The example of a 0-1V input measured with a 3.3V reference can be improved by using a lower reference voltage. For example, the Atmega324 MCU has an internal 10-bit ADC. The ADC reference voltage can be selected to be the MCU supply voltage (3.3V in the example), a reference voltage on an external pin, or an internal 1.1V reference voltage. The 1.1V reference voltage isn’t great; the datasheet specifies a 10% accuracy. But as long as the 0-1V input signal has no excursions beyond 1V, the resolution is 1V/256, or 3.9mV, when using 8-bit data (discarding the lower two bits of the conversion result). Using the full 10-bit result, the resolution would be 1V/1024, or 976µV. Accuracy suffers when using the internal reference, but resolution is much better. Using the 3.3V reference, the voltage range from 1V to 3.3V is essentially wasted because the signal excursion never goes that high. Using a smaller reference voltage allows the full range of ADC values to be applied to the conversion. The ATmega324 also has a 2.56V reference voltage that could similarly be used if the input signal were 0-2V, although the same accuracy issues apply.
External Reference: Staying with the ATmega324 as an example, the MCU also allows an external reference to be applied to the reference pin. For example, the TI LT1009M is a 2.5V reference with a tolerance of 0.2% at 25°C and 1.6% over the full military temperature range (-55°C to 125°C). Using that for the reference on an ATmega324 MCU and with the 0-1V example, the resolution would be 2.5V/1024, or 2.4mV, and the accuracy would be improved to 0.2% (at 25°C). Figure 2 shows how the LT1009M would be connected to an ATmega324 MCU. The unused pin is an adjustment pin to fine-tune the reference voltage if needed.
Scaling: Using a lower reference voltage allows the 0-1V signal to use the full measurement range, but you are limited to the lower accuracy of the internal reference. Scaling does exactly the opposite—it amplifies the signal to cover the full 3.3V range, and allows you to use the higher accuracy of the 3.3V supply. Figure 3 shows an op-amp circuit that would scale the 0-1V input so that it swings 0-3V. This would let the 0-1V input use (almost) the full voltage range with a 3.3V reference. The op-amp is configured as a non-inverting amplifier with gain defined as 1+ R2/R1, for a gain of 3. Note that the resistors are specified as 0.1% parts. If 1% parts are used, the op-amp circuit itself becomes the limiting factor in the accuracy (although not the resolution). Using 0.1% parts minimizes the impact of the scaling amplifier on overall accuracy. Using 0.01% parts would be even better, although those parts will likely cost 10x as much. I left the op-amp unspecified, but it will need to have rail-to-rail inputs and outputs, or else be operated from dual voltages such as +5V and -5V.
With this circuit, almost the full range of the 3.3V reference is used, with a 1V input producing a 10-bit ADC result of 3/3.2mV or 930. This allows you to use a 1% 3.3V reference but apply it to the entire range of the input signal. Note that the accuracy is still limited to 1%, so a 1V input could produce an ADC result from to 921 to 940.
Differential Measurement: In Circuit Cellar, Issue 407, in an article about barometric sensors, I had a sensor that operated from a 5V supply but was read by an MCU operating at 3.3V. The output from the sensor was ratioed to the 5V supply, and there was no way to check the accuracy of the signal, other than assuming it’s within the accuracy of the 5V supply itself. Suppose the 5V supply had a tolerance of 5%, meaning it could be between 4.75V and 5.25V. If I need to measure with 2% accuracy I could use a 1% regulator on the 3.3V supply, but that doesn’t improve the 5% tolerance on the 5V supply.
Figure 4 shows how you can make a differential measurement in a case like that. Two ADC inputs are used on the MPU; one reads the signal from the sensor, and the other reads half the 5V voltage that drives the sensor. Again, 0.1% or 0.01% resistors are needed for the divider. So if the 5V supply is at the low end of its range, 4.75V, the sensor value is multiplied (in software) by 1.052 to compensate for the variation in the 5V supply. This doesn’t compensate for the 3.3V supply tolerance, but it does allow you to compensate for the variation in the 5V supply. With the values shown, the expected value for a 5.000V supply will always be 2.5V, which is 775 from the ADC.
You could do something similar with the 1.1V internal Atmega324 reference. If the 3.3V supply has a 1% accuracy (using the more precise version of the LF33) you can compensate for the 10% tolerance of the internal 1.1V reference by reading the reference voltage. The Atmega324 ADC has an option to read the reference voltage internally, and you don’t need to use another ADC input pin to do so. If your MCU doesn’t have that feature but the internal reference is connected to an external pin, you may be able to read it by using another ADC input. Either way, this is only an advantage if you have a more accurate reference to compare the internal reference against.
Factory reference
Devices such as the Maxim DS4303 (Figure 5) are adjustable precision references with 1mV accuracy. The device operates from 2.4V to 3.6V and contains an internal EEPROM. To calibrate the device, a precise voltage is applied to VIN and the ADJ pin is toggled. The DS4303 will adjust an internal digital to analog converter (DAC) so that the output voltage Vo matches Vin. The value is then stored in the internal EEPROM.
The next time the device is powered up, the output automatically goes to the programmed voltage. Obviously, this requires that a very precise reference voltage be applied to Vin during calibration. Typically, programming of the DS4303 will be performed using a bed-of-nails procedure during production. But the output voltage is only as good as the accuracy of the input voltage applied during calibration.
Many embedded systems need to measure external analog values. Understanding what affects accuracy and resolution, and how they are interrelated, is important for designing a robust embedded application.
RESOURCES
ST LFxx: https://www.st.com/en/power-management/lfxx.html
TI LT1009 datasheet: https://www.ti.com/lit/ds/symlink/lt1009.pdf
DS4303 datasheet: https://www.analog.com/media/cn/technical-documentation/data-sheets/4672.pdf