Remote Observation Station
Remote Observation Station

Have you ever wondered what the birds, deer, or bears were doing in your backyard when you weren’t around? With the Remote Observation Station, you can watch wildlife on your TV in the comfort of your living room. The station includes a camera and transmitter that sends a picture to a TV, which can be up to a mile or two away. The station gets its power from a PV solar panel and a rechargeable battery, which rely on the system’s control board for direction. The control board also produces battery state information, which it overlays on the picture sent to your TV. So, while you’re watching the wildlife, you can also monitor the status of your battery.

The unit integrates six electronic devices, including a CCD video camera, PV solar panel, rechargeable battery, temperature sensor, RF video transmitter, and the system control board (PVCC). The control board is based on the Motorola 68HC908QY4 microcontroller. The board sits at the center of the system, providing a PV charge controller, two high-efficiency voltage regulators, a video sync separator, and an RS-232 serial interface for system configuration.

The PVCC control board provides a simple on/off battery charger using the PV solar panel as a power source. The primary job of the charge controller is to prevent the battery from being overcharged. The control board also adds battery state information in the form of a text overlay (on-screen display, or OSD) to the video signal generated by the CCD camera before it reaches the video transmitter. Additionally, a PC can be connected to the control board via the DB9 connector.

The system has three operating modes: Configuration mode allows you to control user settings with your PC; Charge Control mode with OSD sends the battery’s voltage and temperature to the video signal; and Charge Control mode without OSD is used when you don’t need the diagnostic display. The PVCC configuration utility communicates with the PVCC board while in Configuration mode. With this utility, you can set a variety of options, including the full-charge set point (the off set point) and the PV reconnect set point (the on set point). You can also choose to enable the transmission of an Amateur Radio call sign if a ham frequency is being used.

Supporting Files

Flash Innovation

Contest Ended: June 30, 2003

Keep up-to-date with our FREE Weekly Newsletter!

Don't miss out on upcoming issues of Circuit Cellar.


Note: We’ve made the Dec 2022 issue of Circuit Cellar available as a free sample issue. In it, you’ll find a rich variety of the kinds of articles and information that exemplify a typical issue of the current magazine.

Would you like to write for Circuit Cellar? We are always accepting articles/posts from the technical community. Get in touch with us and let's discuss your ideas.

Supporting Companies

Upcoming Events


Copyright © KCK Media Corp.
All Rights Reserved

Copyright © 2023 KCK Media Corp.

Remote Observation Station

by Circuit Cellar Staff time to read: 2 min